Cooling solutions for AI data centers in India.

We're a cooling consultancy and system integrator. We help you choose the right approach: direct-to-chip, immersion, or rear-door heat exchangers. We deploy and commission it on site, and supply the components, moving AI workloads from air-cooled limits to 30–130 kW per rack.

Supported density
30–130kW / rack
Target PUE
≤ 1.15
Service region
South India
Typical lead time
3–5weeks
DataCool — liquid & air cooling for AI data centers: direct-to-chip, immersion and rear-door HX for 30–130 kW racks. Supply 32°C, return 48°C, CDU, rack, HX.
Reference cooling loop · liquid & air Supply 32 °C · Return 48 °C

01 / The thermal cliff

Air cooling stops working at AI workloads.

A single H100 draws ~700 W. A Blackwell B200 draws ~1,200 W. Pack eight per server, eight servers per rack, and the math breaks the air-cooled envelope. Liquid is no longer a preference. It's the only option that scales.

Air cooling

PRACTICAL CEILING

8–15kW / rack

Hot-aisle/cold-aisle, in-row CRAC, raised floor. Works for general-purpose compute. Fails the moment you try to deploy modern GPU servers at density.

  • Hot-spot formation above 12 kW
  • Throttling under sustained training load
  • PUE typically 1.5–1.8 in tropical climates
  • No path to H100 / Blackwell density
Liquid cooling

PROVEN OPERATING RANGE

30–130kW / rack

Direct-to-chip cold plates, rear-door heat exchangers, or full immersion. Heat removed at the source, water year-round, dramatically lower energy overhead.

  • Sustained turbo on H100 / Blackwell
  • Up to 95% of heat captured in liquid
  • PUE 1.05–1.15 even in Chennai climate
  • Headroom for next-gen accelerators

02 / Our cooling solutions

Liquid where it counts. Air where it fits.

We focus on liquid cooling, direct-to-chip and immersion, and deploy rear-door heat exchangers where an air-side retrofit is the right call. Three approaches, matched to your site, then integrated and supplied end-to-end.

— 01
Liquid · cold plate

Direct-to-chip (DLC)

Cold plates sit straight on the GPU, CPU and memory, with up to ~80% of rack heat captured in liquid. The workhorse for dense AI racks.

  • 30–130 kW / RACK
  • GPU · CPU · MEMORY
  • LOWEST PUE AT DENSITY
Explore CDUs & DLC
— 02
Air + liquid · RDHx

Rear-door HX (RDHx)

A liquid-to-air heat exchanger replaces the rack's rear door, taking the heat before it hits the room. Retrofit a live hall with no change to the IT stack.

  • UP TO ~50 kW / RACK
  • ZERO-DISRUPTION RETROFIT
  • KEEPS YOUR AIR LAYOUT
Explore rear-door HX
— 03
Liquid · immersion

Single-phase immersion

Whole servers submerged in dielectric fluid that stays liquid, circulated to an external heat exchanger. Near-silent, no rack fans.

  • 100+ kW / TANK
  • DIELECTRIC FLUID
  • NO AIR HANDLING
Explore immersion

03 / What we do

A consultancy and system integrator, not just a parts desk.

Three ways we move heat out of your AI hall: advise on what to build, integrate and commission it, and supply the components that make it run.

— 01

Consult

Vendor-neutral advisory before any PO: feasibility, technology selection, PUE and TCO modeling, and design review.

  • FEASIBILITY & CONCEPT
  • TECHNOLOGY SELECTION
  • PUE & TCO MODELING
  • SITE AUDIT & DESIGN REVIEW
Consulting
— 02

Integrate

One chain of custody from PO to go-live: procurement, install, fluid fill, commissioning, and SLA support, including live-hall retrofits.

  • PROCUREMENT & CUSTOMS
  • INSTALL & FLUID FILL
  • COMMISSIONING
  • MONITORING & SLA
System integration
— 03

Supply

Distribution across the stack, with stock held in country for the consumables you need monthly.

  • DIELECTRIC FLUIDS
  • CDUs & MANIFOLDS
  • RDHX & IMMERSION
  • IN-COUNTRY STOCK
Browse products

04 / What we supply

Three product lanes, curated for India.

The components behind the Supply pillar: a focused set of vendors across the cooling stack, sized to what Indian operators actually deploy.

— 01

Dielectric coolant fluids

Single-phase fluids engineered for direct contact with electronics. Long-life, low-GWP, non-conductive.

  • SINGLE-PHASE & DLC FLUIDS
  • LOW-GWP · NON-CONDUCTIVE
  • OEM-APPROVED LISTS
  • IN-COUNTRY STOCK
Explore fluids
— 02

CDUs & manifolds

Coolant Distribution Units sized 70 kW to 2 MW+, paired with row and rack manifolds for direct-to-chip deployments.

  • 70 kW – 2 MW+ CAPACITY
  • IN-ROW · IN-RACK · SIDECAR
  • N · N+1 · 2N PUMPS
  • ROW & RACK MANIFOLDS
Explore CDUs
— 03

Rear-door HX & immersion

Retrofit the room you already have, or build a tank-based hall from day one. Single-phase immersion supported.

  • REAR-DOOR HX · UP TO 50 kW
  • SINGLE-PHASE IMMERSION
  • RETROFIT OR GREENFIELD
Explore immersion

05 / Why DataCool

Specialised. Local. End-to-end.

We don't sell servers, power, or racks. We do one thing: get heat out of your AI hall, as your consultant, integrator, and supplier, on the ground in South India.

/01

South India focus

Chennai, Bengaluru, Hyderabad, Vizag, Kochi. We know the climate, the power situation, the contractors, the customs lanes. Site visits inside 24 hours.

/02

Technical depth, not catalog sales

Thermal load calculations, CDU sizing, fluid compatibility, manifold flow balancing. Our engineers have deployed liquid loops; they don't read off a spec sheet.

/03

End-to-end deployment

Procurement, customs, on-site commissioning, fluid filling, leak testing, monitoring integration, and post-go-live SLA support. One partner, one chain of custody.

Ready when you are

Planning an AI hall? Let's run the numbers.

Send us your rack count, target density, and timeline. We'll come back inside 48 hours with a sized solution and a delivered cost.